【節(jié)能學(xué)院】ASJ系列剩余電流繼電器在海洋平臺(tái)的應(yīng)用

江蘇安科瑞電器制造有限公司 ? 2022-01-05 09:19 ? 次閱讀

摘要

本文通過對(duì)海洋平臺(tái)接地故障的分析,論述了海洋平臺(tái)手持式和移動(dòng)式用電設(shè)備安裝漏電保護(hù)器的必要性,同時(shí)簡(jiǎn)述了漏電保護(hù)器的工作原理

Abstract: Through the analysis of the ground fault of the ocean platform, this paper discusses the necessity of installing the leakage protector on the handheld and mobile electrical equipment of the ocean platform, and briefly describes the working principle of the leakage protector.

關(guān)鍵詞:海洋平臺(tái);IT系統(tǒng);漏電保護(hù)器

Keywords:Ocean platform; IT system;Leakage protector

00 概述

在海洋石油及天然氣開采過程中,海洋平臺(tái)作為油氣采集、臨時(shí)存儲(chǔ)及簡(jiǎn)單處理的重要場(chǎng)所,其危險(xiǎn)性極大。同時(shí),受日曬雨淋、鹽霧侵蝕、用電設(shè)備緊湊及操作空間狹小等諸多因素的影響,海洋平臺(tái)的電氣安全一直存在隱患。為了避免海洋平臺(tái)電氣安全事故的發(fā)生,需要根據(jù)海洋平臺(tái)的環(huán)境特點(diǎn),因地制宜地選擇供配電系統(tǒng)接地形式,并選擇相應(yīng)的接地保護(hù)方式。

In the process of ocean oil and natural gas exploitation,ocean platform are extremely dangerous as important places for oil and gas collection, temporary storage and simple processing. At the same time, affected by many factors such as sun and rain, salt spray erosion, compact electrical equipment, and narrow operating space, there are always hidden dangers in the electrical safety of ocean platform. In order to avoid electrical safety accidents of ocean platform, it is necessary to select the grounding form of the power supply and distribution system according to the environmental characteristics of the ocean platform, and choose the corresponding grounding protection method.

01 海洋平臺(tái)配電系統(tǒng)的特點(diǎn)

低壓配電系統(tǒng)分TN系統(tǒng)、TT系統(tǒng)及IT系統(tǒng)3種形式。每種接地形式的低壓配電系統(tǒng)都有其自身的優(yōu)缺點(diǎn)和適用范圍。設(shè)計(jì)工作者應(yīng)根據(jù)作業(yè)場(chǎng)所的環(huán)境條件、用電設(shè)備的特點(diǎn)和用電要求等因素加以具體選擇。當(dāng)前,海洋平臺(tái)一般使用IT系統(tǒng)供電,這是由其自身的特點(diǎn)決定的:1)海洋平臺(tái)遠(yuǎn)離陸地,對(duì)不間斷供電的要求高。例如平臺(tái)的消防措施和緊急逃生設(shè)施就不允許斷電;2)海洋平臺(tái)環(huán)境惡劣,鹽霧和潮濕容易使用電設(shè)備和供電線路的絕緣損壞,出現(xiàn)接地故障。

The low-voltage power distribution system is divided into three forms:the TN system,the TT system and the IT system. Each type of grounding low-voltage power distribution system has its own advantages, disadvantages and scope of application. Designers should make specific choices based on factors such as the environmental conditions of the workplace, the characteristics of electrical equipment, and electrical requirements. At present, ocean platform generally use IT systems for power supply, which is determined by their own characteristics: 1) ocean platforms are far away from the land and require high uninterrupted power supply. For example, the platform's fire protection measures and emergency escape facilities are not allowed to be powered off; 2) The marine platform has a harsh environment, salt spray and humidity are prone to damage to the insulation of electrical equipment and power supply lines, and ground faults occur.

02 海洋平臺(tái)手持式和移動(dòng)式用電設(shè)備漏電保護(hù)問題

2.1 海洋平臺(tái)手持式和移動(dòng)式用電設(shè)備發(fā)生接地故障一般有以下原因;a)手持式和移動(dòng)式用電設(shè)備由于需要頻繁移動(dòng),電纜與用電設(shè)備的接頭容易松脫,使相線碰設(shè)備外殼而發(fā)生接地故障;b)手持式和移動(dòng)式用電設(shè)備在使用過程中電纜反復(fù)彎曲,使芯線部分折斷,刺破電纜絕緣與外部可導(dǎo)電部分接觸而發(fā)生接地故障。

Ground faults of handheld and mobile electrical equipment on ocean platforms are generally due to the following reasons; a) Hand-held and mobile electrical equipment need to be moved frequently, so the cable and electrical equipment’s joints are easy to loosen, causing the phase lines to touch. Ground fault occurs on the equipment shell; b) The cable repeatedly bends during the use of handheld and mobile electrical equipment, causing the core wire to be broken, piercing the cable insulation and contacting the external conductive part to cause a ground fault.

2.2 海洋平臺(tái)手持式和移動(dòng)式用電設(shè)備接地故障分析

Ground fault analysis of handheld and mobile electrical equipment on ocean platforms

a)單相接地故障。國(guó)際電工委員會(huì)標(biāo)準(zhǔn)IEC4.79(電流通過人體的效應(yīng))確定,通過人體的交流50Hz電流不超過30mA時(shí),人體不會(huì)發(fā)生心室纖維性顫動(dòng)而死亡,它與人體潮濕程度、接觸電壓高低沒有直接關(guān)系。大多數(shù)海洋平臺(tái)低壓配電系統(tǒng)接地形式一直沿用中性點(diǎn)不接地的IT系統(tǒng),這樣如果發(fā)生直接觸及單相帶電導(dǎo)體、單相接地或者間接觸點(diǎn)故障時(shí),單相接地故障電流為另外兩相對(duì)地電容電流的向量和,通常兩相對(duì)地電容電流的向量和很小,即故障電流很小,這種情況下不會(huì)構(gòu)成電擊危險(xiǎn),因此也可以不切斷供電電源。但是,隨著海洋平臺(tái)用電設(shè)備的增多,電力電纜線路隨之增多,電容電流相應(yīng)的增大,發(fā)生故障時(shí)單相接地電流也隨之增大。如果用電設(shè)備的外殼沒有可靠接地或者接地線斷開時(shí),單相接地故障電流只能通過人體形成回路,當(dāng)通過人體的交流50Hz電流超過30mA時(shí),人體就可能會(huì)因發(fā)生心室纖維性顫動(dòng)而死亡。在低壓配電系統(tǒng)中,用電設(shè)備的一相絕緣擊穿,使其設(shè)備外殼帶電。當(dāng)單相接地故障電流Id=Ia+Ib≥30mA時(shí),就超過了人體能承受的交流電流安全閾值,一定要立即切斷供電以確保安全。此時(shí)在用電設(shè)備處安裝漏電保護(hù)器是唯一的解決辦法

a)Single-phase ground fault. The International Electrotechnical Commission standard IEC4.79 (Effect of current passing through the human body) determines that when the AC 50Hz current through the human body does not exceed 30mA, the human body will not die due to ventricular fibrillation. It has no direct relationship with the humidity of the human body and the level of contact voltage.Most of the low-voltage power distribution systems of ocean platforms have always used IT systems with ungrounded neutral points, so that if direct contact with single-phase live conductors, single-phase grounding or indirect contact failure occurs, the single-phase grounding fault current is the other two relative.The vector sum of the ground capacitance current is usually very small, that is, the fault current is very small. In this case, there is no danger of electric shock. Therefore, the power supply may not be cut off. However, as the number of electrical equipment used on ocean platforms increases, power cable lines increase accordingly, and the capacitive current increases accordingly, and the single-phase ground current also increases when a fault occurs. If the shell of the electrical equipment is not reliably grounded or the grounding wire is disconnected, the single-phase ground fault current can only form a loop through the human body. When the AC 50Hz current through the human body exceeds 30mA, the human body may be caused by ventricular fibrillation. die. In the low-voltage power distribution system, one-phase insulation breakdown of electrical equipment causes the equipment shell to become live. When the single-phase ground fault current Id=Ia+Ib≥30mA, it exceeds the safety threshold of AC current that the human body can withstand, and the power supply must be cut off immediately to ensure safety. At this time, installing a leakage protector at the electrical equipment is the only solution.叫

b)異相接地故障。當(dāng)發(fā)生單相接地故障時(shí),另外兩相對(duì)地電壓升高,電氣設(shè)備的絕緣要求承受較高的電壓,可能會(huì)導(dǎo)致絕緣破壞使故障進(jìn)一步擴(kuò)大,照成異相接地故障的發(fā)生。根據(jù)《低壓配電設(shè)計(jì)規(guī)范》GB50054-1995中第4.4.14條:IT系統(tǒng)外露可導(dǎo)電部分可用共同的接地極接地,亦可個(gè)別地或成組地用單獨(dú)的接地極接地。當(dāng)外露可導(dǎo)電部分為共同接地,則發(fā)生第二次異相接地故障時(shí),故障回路的切斷應(yīng)符合TN系統(tǒng)接地故障保護(hù)的要求。海洋平臺(tái)是鋼結(jié)構(gòu)體,本身就是導(dǎo)體,相當(dāng)于用電設(shè)備外露可導(dǎo)電部分共用接地極接地。當(dāng)發(fā)生異相接地故障時(shí),故障回路的切斷應(yīng)符合TN系統(tǒng)接地故障保護(hù)的要求。按照規(guī)范要,在TN系統(tǒng)中,手持式和移動(dòng)式用電設(shè)備應(yīng)設(shè)置漏電保護(hù)器。

b)Out-of-phase grounding fault. When a single-phase grounding fault occurs, the other two phase-to-ground voltages increase, and the insulation of electrical equipment is required to withstand a higher voltage, which may cause insulation damage and further enlarge the fault, which will result in an out-of-phase grounding fault. According to Article 4.4.14 of "Code for Low-Voltage Power Distribution Design" GB50054-1995: The exposed conductive parts of the IT system can be grounded with a common grounding electrode, or individually or in groups with separate grounding electrodes. When the exposed conductive parts are grounded together, when the second out-of-phase ground fault occurs, the cut-off of the fault circuit should meet the requirements of TN system ground fault protection. The offshore platform is a steel structure, which itself is a conductor, which is equivalent to the common grounding electrode of the exposed conductive parts of the electrical equipment. When an out-of-phase ground fault occurs, the disconnection of the fault circuit should meet the requirements of TN system ground fault protection. According to the specifications, in the TN system, handheld and mobile electrical equipment should be equipped with leakage protectors.

03 產(chǎn)品概述

剩余電流繼電器是由剩余電流互感器來檢測(cè)剩余電流,并在規(guī)定條件下,當(dāng)剩余電流達(dá)到或超過給定值時(shí),使電器的一個(gè)或多個(gè)電氣輸出電路中的觸點(diǎn)產(chǎn)生開閉動(dòng)作的開關(guān)電器。

下面介紹三種常見的漏電情況。

The residual current relay is a residual current transformer to detect the residual current, and under specified conditions, when the residual current reaches or exceeds a given value, one or more electrical output circuit contacts in the electrical appliance will open and close. Switch electrical appliances.

Here are three common leakage situations.

3.1 防直接接觸電擊必須采用I△n≤30mA的高靈敏度的RCD。

High-sensitivity RCD with I△n≤30mA must be used to prevent direct contact and electric shock.

eb584c54-6a5e-11ec-ad3b-dac502259ad0.png

3.2 防間接接觸電擊可采用I△n大于30mA的中靈敏度的RCD。

The medium sensitivity RCD with I△n greater than 30mA can be used to prevent indirect contact and electric shock.

eb999dd0-6a5e-11ec-ad3b-dac502259ad0.png

3.3 防火RCD需采用4極或2極RCD。

A 4-pole or 2-pole RCD shall be used for fireproof RCD.

ebd7cbc8-6a5e-11ec-ad3b-dac502259ad0.png

對(duì)于IT系統(tǒng),按規(guī)定采用剩余電流繼電器。為防止系統(tǒng)絕緣降低和作為二次故障后備保護(hù),依據(jù)接線型式,采用類似 TT 或 TN 系統(tǒng)的保護(hù)措施。首先應(yīng)采用絕緣監(jiān)視裝置,預(yù)測(cè)一次故障。

For theIT systems, residual current relays are used as required. In order to prevent the insulation of the system from degrading and as a secondary fault backup protection, according to the wiring type, a protective measure similar to the TT or TN system is adopted. First, an insulation monitoring device should be used to predict a failure.

ebffbf20-6a5e-11ec-ad3b-dac502259ad0.png

對(duì)于TT系統(tǒng),推薦采用剩余電流繼電器。因?yàn)楫?dāng)發(fā)生單相接地故障時(shí),故障電流很小,且較難估計(jì),達(dá)不到開關(guān)的動(dòng)作電流,外殼上將出現(xiàn)危險(xiǎn)電壓。此時(shí)N線必須穿過剩余電流互感器。

For the TT system, a residual current relay is recommended. Because when a single-phase ground fault occurs, the fault current is very small and difficult to estimate. If the operating current of the switch is not reached, a dangerous voltage will appear on the housing. At this time, the N wire must pass through the residual current transformer.

ec46da86-6a5e-11ec-ad3b-dac502259ad0.png

對(duì)于TN-S系統(tǒng),可采用剩余電流繼電器。更快速靈敏切斷故障,以提高安全可靠性,此時(shí) PE 線不得穿過互感器,N 線必須穿互感器,且不得重復(fù)接地。

For the TN-S system, a residual current relay can be used. Cut off the fault more quickly and sensitively to improve safety and reliability. At this time, the PE wire must not pass through the transformer, and the N wire must pass through the transformer, and it must not be grounded repeatedly.

ec7fecd6-6a5e-11ec-ad3b-dac502259ad0.png

對(duì)于TN-C系統(tǒng),不能采用剩余電流繼電器。因?yàn)?PE 線和 N 線合一,若 PEN 線不重復(fù)接地,當(dāng)外殼帶電,互感器進(jìn)出電流相等,ASJ拒動(dòng);若PEN線重復(fù)接地,部分單相電流將流入重復(fù)接地,達(dá)一定值后,ASJ 誤動(dòng)。需將TN-C系統(tǒng)改造成TN-C-S系統(tǒng),同TN-S系統(tǒng),再將剩余電流互感器接入TN-S系統(tǒng)中。

For the TN-C systems, residual current relays cannot be used. Because the PE wire and the N wire are integrated, if the PEN wire is not repeatedly grounded, when the shell is energized, the current in and out of the transformer is equal, and the ASJ refuses to move; if the PEN wire is repeatedly grounded, part of the single-phase current will flow into the repeated grounding. After reaching a certain value, ASJ malfunctioned. It is necessary to transform the TN-C system into a TN-C-S system, which is the same as the TN-S system, and then connect the residual current transformer to the TN-S system.

ecab374c-6a5e-11ec-ad3b-dac502259ad0.png??????????????

04 產(chǎn)品簡(jiǎn)介

安科瑞電氣ASJ系列剩余電流繼電器能夠滿足上述幾種漏電情況的防護(hù),與遙控跳閘開關(guān)聯(lián)用,及時(shí)切斷電源,防止間接接觸、限制漏電電流。也可以直接作為信號(hào)繼電器,監(jiān)控電力設(shè)備。特別適用于學(xué)校、商廈、工廠車間、集貿(mào)市場(chǎng)、工礦企業(yè)、國(guó)家重點(diǎn)消防單位、智能大廈與小區(qū),地鐵、石油化工、電信及國(guó)防等部門用電的安全保護(hù)。

AcrelElectric's ASJ series residual current relay can meet the protection of the above-mentioned leakage conditions, and it can be used in conjunction with a remote trip switch to cut off the power supply in time to prevent indirect contact and limit the leakage current. It can also be directly used as a signal relay to monitor power equipment. It is especially suitable for the safety protection of electricity consumption in schools, commercial buildings, factory workshops, bazaars, industrial and mining enterprises, national key fire protection units, smart buildings and communities, subways, petrochemicals, telecommunications and national defense departments.

ASJ系列產(chǎn)品主要有兩種安裝方式,ASJ10系列為導(dǎo)軌安裝,外形和功能如下表所示:

ecdec6c0-6a5e-11ec-ad3b-dac502259ad0.png

The ASJ series products mainly have two installation methods. ASJ10 series are rail-mounted installations. The appearance and functions are shown in the following table:

ed00ddbe-6a5e-11ec-ad3b-dac502259ad0.png

ASJ20系列為面板安裝,外形和功能如下表所示:

ed30f666-6a5e-11ec-ad3b-dac502259ad0.png

ASJ20 series are panel mounted, the appearance and functions are shown in the following table:

ed61784a-6a5e-11ec-ad3b-dac502259ad0.png

其中AC型和A型剩余電流繼電器的區(qū)別是:AC型剩余電流繼電器是對(duì)突然施加或緩慢上升的剩余正弦交流電流能確保脫扣的剩余電流繼電器,主要監(jiān)測(cè)正弦交流信號(hào)。A型剩余電流繼電器是對(duì)突然施加的或緩慢上升的剩余正弦交流電流和剩余脈動(dòng)直流電流能確保脫扣的剩余電流繼電器,主要監(jiān)測(cè)正弦交流信號(hào)和脈沖直流信號(hào)。

Among them, the difference between AC type and A type residual current relay is: AC type residual current relay is a residual current relay that can ensure the tripping of the residual sinusoidal alternating current that is suddenly applied or slowly rising, and it mainly monitors sinusoidal alternating current signals. Type A residual current relay is a residual current relay that can ensure the tripping of residual sinusoidal alternating current and residual pulsating direct current that is applied suddenly or slowly, and mainly monitors sinusoidal alternating current signals and pulsed direct current signals.

儀表具體的接線端子和典型接線如下所示:

The specific wiring terminals and typical wiring of the instrument are as follows:

ed9ce5ec-6a5e-11ec-ad3b-dac502259ad0.png??????????????

05 結(jié)語

以往海洋平臺(tái)的電氣設(shè)計(jì)中,對(duì)于手持式和移動(dòng)式用電設(shè)備的配電保護(hù),基本沒有或很少裝設(shè)漏電保護(hù)器,更有設(shè)計(jì)者認(rèn)為,在海洋平臺(tái)的IT供電系統(tǒng)中手持式和移動(dòng)式用電設(shè)備沒有必要裝設(shè)漏電保護(hù)器,從上看來,這種想法只是考慮了其中的一個(gè)方面,是片面的。ASJ系列剩余電流繼電器產(chǎn)品能夠監(jiān)測(cè)線路中的漏電流,當(dāng)漏電流達(dá)到或者超過設(shè)定值時(shí),內(nèi)部繼電器動(dòng)作,發(fā)出告警,并能與斷路器開關(guān)聯(lián)動(dòng),快速切斷線路,保證線路安全。

In the previous electrical design of ocean platforms, there were basically no or seldom installed leakage protectors for the power distribution protection of handheld and mobile electrical equipment. More designers believe that in the IT power supply system of ocean platforms, handheld and it is not necessary to install a leakage protector for mobile electrical equipment. From the above point of view, this idea only considers one aspect of it and is one-sided. ASJ series residual current relay products can monitor the leakage current in the line. When the leakage current reaches or exceeds the set value, the internal relay will act to issue an alarm, and can be linked with the circuit breaker switch to quickly cut off the line to ensure line safety.

edc4547e-6a5e-11ec-ad3b-dac502259ad0.png

請(qǐng)旋轉(zhuǎn)手機(jī)

查看更多精彩

點(diǎn)我

edef660a-6a5e-11ec-ad3b-dac502259ad0.jpg?
聲明:本文內(nèi)容及配圖由入駐作者撰寫或者入駐合作網(wǎng)站授權(quán)轉(zhuǎn)載。文章觀點(diǎn)僅代表作者本人,不代表電子發(fā)燒友網(wǎng)立場(chǎng)。文章及其配圖僅供工程師學(xué)習(xí)之用,如有內(nèi)容侵權(quán)或者其他違規(guī)問題,請(qǐng)聯(lián)系本站處理。 舉報(bào)投訴
  • 繼電器
    +關(guān)注

    關(guān)注

    132

    文章

    5361

    瀏覽量

    149416
收藏 人收藏

    評(píng)論

    相關(guān)推薦

    ASJ系列剩余電流繼電器:施工現(xiàn)場(chǎng)的“安全衛(wèi)士”

    設(shè)備損壞,更可能引發(fā)嚴(yán)重的人身傷害事故。因此,如何有效防范和處理施工現(xiàn)場(chǎng)的漏電問題成為了一個(gè)亟待解決的問題。本文將詳細(xì)介紹ASJ系列剩余電流繼電器施工現(xiàn)場(chǎng)的應(yīng)用,展現(xiàn)其
    的頭像 發(fā)表于 12-20 09:33 ?136次閱讀
    <b class='flag-5'>ASJ</b><b class='flag-5'>系列</b><b class='flag-5'>剩余電流繼電器</b>:施工現(xiàn)場(chǎng)的“安全衛(wèi)士”

    ASJ系列剩余電流動(dòng)作繼電器安裝使用說明書 V2.0

    ASJ系列剩余電流繼電器說明書?
    發(fā)表于 12-16 14:21 ?0次下載

    ASJ系列剩余電流動(dòng)作繼電器及監(jiān)控產(chǎn)品解決方案

    ASJ系列剩余電流動(dòng)作繼電器及監(jiān)控產(chǎn)品解決方案
    的頭像 發(fā)表于 11-27 11:45 ?202次閱讀
    <b class='flag-5'>ASJ</b><b class='flag-5'>系列</b><b class='flag-5'>剩余電流</b>動(dòng)作<b class='flag-5'>繼電器</b>及監(jiān)控產(chǎn)品解決方案

    智能剩余電流繼電器有哪些功能

    、寫字樓等場(chǎng)所,大量的電氣設(shè)備(如照明系統(tǒng)、空調(diào)系統(tǒng)、電梯等)需要保護(hù)。智能剩余電流繼電器可以對(duì)整個(gè)建筑的電氣系統(tǒng)進(jìn)行監(jiān)測(cè)和保護(hù),保障人員安全和設(shè)備正常運(yùn)行。 工業(yè)場(chǎng)所:工廠中有各種復(fù)雜的電氣設(shè)備和生產(chǎn)線,存
    的頭像 發(fā)表于 11-19 10:43 ?171次閱讀
    智能<b class='flag-5'>剩余電流繼電器</b>有哪些功能

    剩余電流繼電器溫室大棚漏電保護(hù)中的應(yīng)用研究

    ASJ系列剩余電流繼電器通過實(shí)時(shí)監(jiān)測(cè)電氣線路的剩余電流,可以及時(shí)發(fā)現(xiàn)接地故障并切斷電源,防止火災(zāi)、設(shè)備損壞和人身傷害。本文將詳細(xì)分析ASJ
    的頭像 發(fā)表于 11-12 15:49 ?237次閱讀

    配電柜剩余電流繼電器的應(yīng)用

    。本文將探討剩余電流繼電器現(xiàn)代配電系統(tǒng)中的應(yīng)用,并重點(diǎn)介紹ASJ系列剩余電流繼電器的特點(diǎn)與優(yōu)勢(shì)。 剩余
    的頭像 發(fā)表于 11-07 13:17 ?291次閱讀
    配電柜<b class='flag-5'>剩余電流繼電器</b>的應(yīng)用

    剩余電流繼電器體育場(chǎng)館的應(yīng)用

    現(xiàn)代社會(huì),體育場(chǎng)館作為大型活動(dòng)、體育賽事和公共健身的重要場(chǎng)所,其電氣系統(tǒng)的安全性和穩(wěn)定性至關(guān)重要。剩余電流繼電器,作為一種基于漏電保護(hù)原理的電氣安全裝置,體育場(chǎng)館中的應(yīng)用日益廣泛。本文將從
    的頭像 發(fā)表于 10-15 14:16 ?351次閱讀
    <b class='flag-5'>剩余電流繼電器</b><b class='flag-5'>在</b>體育場(chǎng)館的應(yīng)用

    剩余電流繼電器的基本原理和作用

    剩余電流繼電器作為一種重要的電氣保護(hù)裝置,電力系統(tǒng)、建筑電氣、工業(yè)自動(dòng)化等領(lǐng)域中發(fā)揮著關(guān)鍵作用。下面將詳細(xì)闡述剩余電流繼電器的基本工作原理和作用。
    的頭像 發(fā)表于 10-05 16:16 ?628次閱讀

    安科瑞ASJ系列剩余電流繼電器工業(yè)領(lǐng)域中的應(yīng)用

    安科瑞徐赟杰18706165067 1.概述 工業(yè)應(yīng)用中,剩余電流繼電器與外部剩余電流互感器結(jié)合使用以檢測(cè)和評(píng)估接地故障電流。它們也可以與保護(hù)裝置結(jié)合使用,以實(shí)現(xiàn)電路的斷開,從而實(shí)現(xiàn)
    的頭像 發(fā)表于 09-27 09:20 ?317次閱讀
    安科瑞<b class='flag-5'>ASJ</b><b class='flag-5'>系列</b><b class='flag-5'>剩余電流繼電器</b><b class='flag-5'>在</b>工業(yè)領(lǐng)域中的應(yīng)用

    電壓繼電器電流繼電器的對(duì)比

    電力系統(tǒng)和自動(dòng)化控制中,繼電器作為一種重要的電子控制器件,起著至關(guān)重要的作用。其中,電壓繼電器電流繼電器作為繼電器的兩種常見類型,各自具
    的頭像 發(fā)表于 06-27 11:34 ?1741次閱讀

    電壓繼電器電流繼電器線圈的區(qū)別

    電壓繼電器電流繼電器是兩種常見的電氣繼電器,它們電氣控制系統(tǒng)中發(fā)揮著重要的作用。盡管它們的基本功能都是實(shí)現(xiàn)電路的自動(dòng)控制,但它們工作原
    的頭像 發(fā)表于 06-24 11:16 ?1242次閱讀

    安科瑞ASJ系列剩余電流動(dòng)作繼電器應(yīng)用介紹

    進(jìn)行接地故障保護(hù),防止 接地故障電流引起的設(shè)備損壞和電氣火災(zāi)事故,也可用來對(duì)人身觸電危險(xiǎn)提供間接接觸保護(hù)。 ASJ系列剩余電流繼電器特別適用于學(xué)校、商廈、工廠車間、集貿(mào)市場(chǎng)、工礦企業(yè)、
    的頭像 發(fā)表于 04-19 13:57 ?396次閱讀
    安科瑞<b class='flag-5'>ASJ</b><b class='flag-5'>系列</b><b class='flag-5'>剩余電流</b>動(dòng)作<b class='flag-5'>繼電器</b>應(yīng)用介紹

    電流繼電器的工作原理 過電流繼電器怎么選型?

    電流繼電器的工作原理 過電流繼電器怎么選型? 過電流繼電器是一種常用于電路保護(hù)的電氣設(shè)備。其主要功能是監(jiān)測(cè)電路中的電流是否超過了額定值,并在超過額定值時(shí)切斷電路,以防止設(shè)備或電路的過
    的頭像 發(fā)表于 03-06 16:15 ?2094次閱讀

    ASJ20-LD1A智能剩余電流繼電器 棒狀LED指示 1路A型剩余電流測(cè)量

    ASJ 系列剩余電流動(dòng)作繼電器可與低壓斷路器或低壓接觸器等組成組合式剩余電流保護(hù)裝置,主要適用于交流 50Hz,額定電壓 400V 及以下的
    的頭像 發(fā)表于 02-19 15:14 ?436次閱讀
    <b class='flag-5'>ASJ</b>20-LD1A智能<b class='flag-5'>剩余電流繼電器</b> 棒狀LED指示 1路A型<b class='flag-5'>剩余電流</b>測(cè)量

    安科瑞電力繼電器ASJ10L-LD1A智能剩余電流繼電器

    安科瑞 程瑜 1.自恢復(fù)式過欠壓保護(hù)器 安科瑞ASJ10L-LD1A ASJ系列剩余電流動(dòng)作繼電器可與低壓斷路器或低壓接觸器等組裝成組合式的
    的頭像 發(fā)表于 02-02 15:04 ?579次閱讀
    安科瑞電力<b class='flag-5'>繼電器</b><b class='flag-5'>ASJ</b>10L-LD1A智能<b class='flag-5'>剩余電流繼電器</b>
    主站蜘蛛池模板: 手机在线观看无码日韩视频 | 日韩视频中文在线一区 | jaPanesmature儿母 japanese幼儿videos | 他揉捏她两乳不停呻吟口述 | 日韩亚洲欧洲在线rrrr片 | 亚洲 欧美 日韩 国产 视频 | 69精品人妻一区二区三区蜜桃 | 欧美一区二区视频高清专区 | 午夜色网站 | 亚洲中文字幕在线第六区 | 717影院理论午夜伦不卡久久 | 国产麻豆精品传媒AV国产在线 | 黄色软件色多多 | 久久在精品线影院精品国产 | 国产乱辈通伦影片在线播放亚洲 | 欧美性XXXXX极品娇小 | 征服艳妇后宫春色 | 久久re热线视频国产 | 成年人在线视频免费观看 | 久久水蜜桃亚洲AV无码精品偷窥 | 欧美另类jizzhd | 麻花传媒XK在线观看 | 老头xxx | 欧美日韩亚洲一区二区三区在线观看 | 99热久久爱五月天婷婷 | 囯产愉拍亚洲精品一区 | 羞羞漫画视频 | 久久视频在线视频 | 人人超碰97caoporen国产 | 思思99热久久精品在线6 | 日日日操操操 | 精品国产品国语在线不卡丶 | 天美麻豆成人AV精品视频 | 在线 国产 欧美 亚洲 天堂 | 欧美阿v在线免播播放 | 欧美18精品久久久无码午夜福利 | 亚洲色图激情文学 | 99久久国产露脸精品国产麻豆 | 精品久久香蕉国产线看观看麻豆 | 久久精品无码一区二区日韩av | 国产高清视频a在线大全 |