Three-State Procedure
To avoid unwanted click-and-pop at shutdown, use the following procedure (Figure 2):
- If the audio source is already muted, then go to step 4.
- Set the outputs to mute mode by setting CTRL2.MD23[1:0] = CTRL2.MD01[1:0] = 01.
- Wait at least 50ms to ensure no click-and-pop from a 20Hz signal.
- Three-state the outputs by setting CTRL2.MD23[1:0] = CTRL2.MD01[1:0] = 00.
Figure 2. Three-State procedure.
Shutdown Procedure
To avoid unwanted click-and-pop at shutdown, use the following procedure (Figure 3):
- Three-state the outputs by following the three-state procedure outlined above.
- Enter standby mode by setting CTRL2.STBY = 1.
- Pull the EN pin low.
Figure 3. Shutdown procedure.