光模塊故障定位常用命令
根據光模塊的告警信息查找故障原因:
displayinterfacetransceiver
查看光模塊光功率是否正常
displayinterfacetransceiververbose
根據光模塊的告警信息查找故障原因
執行命令display interface transceiver查看“Alarm information”下光模塊是否有告警信息。
displayinterface10ge1/0/1transceiver 10GE1/0/1transceiverinformation: ------------------------------------------------------------------- Commoninformation: TransceiverType:10GBASE_SR ConnectorType:LC Wavelength(nm):850 TransferDistance(m):30(62.5um/125umOM1) 80(50um/125umOM2) 300(50um/125umOM3) 400(50um/125umOM4) DigitalDiagnosticMonitoring:YES VendorName:HUAWEI VendorPartNumber:02318169 OrderingName: ------------------------------------------------------------------- Manufactureinformation: Manu.SerialNumber:AQG269Y ManufacturingDate:2013-10-20 VendorName:HUAWEI ------------------------------------------------------------------- Alarminformation: -------------------------------------------------------------------
如果出現LOS Alarm告警,則說明對端沒有信號發送過來,在接口模式下執行命令display this查看兩端端口是否shutdown,如果端口shutdown了,則執行undo shutdown操作。
查看光模塊光功率是否正常
執行display interface transceiver verbose命令查看光模塊發送或接收光功率方面的信息,與光模塊的標稱光功率進行對比判斷。光模塊的診斷信息中,可以查看當前發送和接收的光功率值,以及默認的最高和最低功率值。
displayinterface10ge1/0/1transceiververbose 10GE1/0/1transceiverinformation: ------------------------------------------------------------------- Commoninformation: TransceiverType:10GBASE_SR ConnectorType:LC Wavelength(nm):850 TransferDistance(m):30(62.5um/125umOM1) 80(50um/125umOM2) 300(50um/125umOM3) 400(50um/125umOM4) DigitalDiagnosticMonitoring:YES VendorName:HUAWEI VendorPartNumber:02318169 OrderingName: ------------------------------------------------------------------- Manufactureinformation: Manu.SerialNumber:AQG269Y ManufacturingDate:2013-10-20 VendorName:HUAWEI ------------------------------------------------------------------- Alarminformation: ------------------------------------------------------------------- Diagnosticinformation: Temperature(Celsius):33.68 Voltage(V):3.29 BiasCurrent(mA):7.97 BiasHighThreshold(mA):13.20 BiasLowThreshold(mA):4.00 CurrentRXPower(dBm):-2.15 DefaultRXPowerHighThreshold(dBm):1.00 DefaultRXPowerLowThreshold(dBm):-11.90 CurrentTXPower(dBm):-2.07 DefaultTXPowerHighThreshold(dBm):1.00 DefaultTXPowerLowThreshold(dBm):-9.30 -------------------------------------------------------------------
如果接收功率低(Current RX Power < Default RX Power Low Threshold),說明本端接收到的信號過低,則可能出現端口不UP或者UP后報文收發有丟棄,此時請先排查傳輸距離是否過遠,超出了該光模塊的傳輸距離,再排查光模塊、光纖是否有損壞。
如果接收功率高(Current RX Power > Default RX Power High Threshold),說明本端接收到的信號過高,可能原因是該光模塊為長距光模塊,而實際傳輸距離太短,導致信號未衰減,此時應在光模塊上增加光衰,以對光模塊進行保護。
如果發送功率低(Current TX Power < Default TX Power Low Threshold),說明該光模塊發送信號不好或光模塊本身故障,可能會導致對端接收功率低,而造成端口不UP或者UP后報文收發有丟棄,請與技術支持人員聯系。
如果發送功率高(Current TX Power > Default TX Power High Threshold),說明該光模塊發送信號太強,可能會導致對端接收功率高,而造成對端光模塊因接收功率持續過高而燒壞,可能原因是本端光模塊故障,建議更換光模塊。
因此,在端口插入光模塊并對接成功后,要對發送或接收光功率方面的告警信息進行排查,避免因功率過低或者過高造成流量或者光模塊不正常。